  3-33-1, minami-otsuka, toshima-ku, tokyo, 170-8451, japan tel: +81 3 5927 1020 http://www.sanyodenki.com the names of companies and/or their products speci?ed in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. ?san ace? is a trademark of sanyo denki co.,ltd. speci?cations are subject to change without notice. the products shown in this catalog are subject to japanese export control law. diversion contrary to the law of exporting country is prohibited. to protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. notice catalog no. c1032b001 ?13.12 option 10.5 0.5 4 - 11 0.5 124 1 104.8 0.3 124 1 104.8 0.3 4 - 4.3 0.3 4 - 2 0.5 resin filter kits model: 109-1000f13 (13ppi), 109-1000f20 (20ppi), 109-1000f30 (30ppi), 109-1000f40 (40ppi) plug cord model: 489-1635-l 10, 489-1635-l 21 42. 2 1.6 1.6 113 148 130 152.5 1.5 ` 0.5 5 1 0 4.3 0.3 outlet side 152.5 0.5 5 1 0 113 4.3 0.3 18.6 130 148 inlet side, outlet side 1.6 1.6 finger guards model: 109-019c surface treatment: nickel-chrome plating (silver) : 109-019h : cation electropainting (black) color model: 109-019e surface treatment: nickel-chrome plating (silver) : 109-019k : cation electropainting (black) color model l 10 l 21 power cord length (mm) 1,000 2,100 wiring harness for sensor model: 489-1636 pre-soldered 1000 20 10 1 pre-soldered 50 5 10 2 l 20 4 17 10 15.5 8 10 8 4 common speci?cations material ?????????????????????????? expected life ????????????????????? motor protection system ?????????? dielectric strength ???????????????? sound pressure level (spl) ???????? operating temperature ???????????? storage temperature ?????????????? mass ????????????????????????????? frame: plastics (flammability: ul94v-0), impeller: plastics (flammability: ul94v-1) refer to speci?cations (l10: survival rate: 90% at 60 , rated voltage, and continuously run in a free air state) burnout protection at locked rotor condition 50/60 hz, 1,500 vac, 1 minute (between power terminal and frame or between lead conductor and frame) expressed as the value at 1 m from air inlet side refer to speci?cations (non-condensing) 30 to 75 (non-condensing) approx. 290 g 120 120 38 mm [ m 3 /min ] [ cfm ] [ pa ] [ inchh 2 o ] model no. rated voltage [v] operating voltage range [v] rated current [a] frequency (note) [hz] rated input [w] max. air flow max. static pressure spl [ db(a)] operating temperature [ ] expected life [h ] rated speed min -1 0.08 9AD1201H12 4.4 3,250 3.0 106 84 0.34 42 100 to 240 90 to 264 20 to 75 60,000 50/60 note: 50/60 hz compatible. available options: pulse sensor lock sensor low speed sensor please contact us for details on the following speci?cations: speci?cations the model no. below has ribs and no sensors. for models without ribs, append "1" to the model no. (ribless model depicted) features low power consumption power consumption is reduced by approximately 72% compared with our conventional ac fan. * long life the san ace 120ad has an expected life of 60,000 hours (approximately 6 years), approximately 2.4 times that of our conventional ac fan. * wide range a rated voltage range of 100 to 240 vac allows for usage in both 100 vac and 200 vac systems. rotation speed remains constant even at different input voltages. * our conventional ac fan is 120 x 120 x 38 mm san ace 120 , model no. 109s072ul at a frequency of 60 hz. ac fan 120 9ad type
120 120 38 mm 135 104.8 0.3 4- 4.5 11 8 104.8 0.3 11 8 outlet side 127 104.8 0.3 4- 4.5 11 8 104.8 0.3 11 8 inlet side reference dimension of mounting holes and vent opening (unit : mm) speci?cations for low-speed sensors v ce 27.6 v dc max. ic 10 ma max. v ce ( sat ) 1.0 v max. sensor scheme h h l fan power fan speed trip point sensor output startup delay detection delay example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. h h l fan power fan speed trip point sensor output startup delay detection delay example 1: when steady running v ce ( sat ) dimensions (unit : mm) (with ribs) typical standard model: 9ad1201h1h output circuit: open collector inside of dc fan pull-up resistor pull-up voltage 4 to 27.6 v dc photocoupler ic 10 ma max. sensor sensor output ( v ce ) air flow direction rotating direction air flow direction rotating direction lead wire mounting hole a wg24 ul1007 standard with sensor 1200.8 1200.8 104.80.3 104.80.3 4- 4.30.3 10010 380.5 60.5 60.5 1200.8 1200.8 104.80.3 104.80.3 4- 4.30.3 380.5 60.5 60.5 mounting hole connector: tyco electronics amp 171822-2 (pin1 sensor output: yellow pin2 : black) contact: tyco electronics amp 170262-1 120 9ad type startup delay: 18 3 sec. detection delay: 3 sec. max. trip point: 1700 min -1 * recommended connectors and contacts are listed below. connector: tyco electronics amp 172211-2 contact: tyco electronics amp 170376-1 air flow - static pressure characteristics wiring diagram (cfm) ( m 3 /min ) ( pa ) ( inch h 2 o ) 90 50 70 60 80 40 30 10 20 0 1 2 3 100 to 240 v 50/60 hz 4 0 50 100 150 0.4 0.2 0.3 0.1 0 fan fan photo coupler yellow black 10 ma max. +4 to 27.6 v dc senser output gnd (0 v) standard with sensor static pressure air ?ow ac power supply ac power supply pull-up resistor
120 120 38 mm 135 104.8 0.3 4- 4.5 11 8 104.8 0.3 11 8 outlet side 127 104.8 0.3 4- 4.5 11 8 104.8 0.3 11 8 inlet side reference dimension of mounting holes and vent opening (unit : mm) speci?cations for low-speed sensors v ce 27.6 v dc max. ic 10 ma max. v ce ( sat ) 1.0 v max. sensor scheme h h l fan power fan speed trip point sensor output startup delay detection delay example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. h h l fan power fan speed trip point sensor output startup delay detection delay example 1: when steady running v ce ( sat ) dimensions (unit : mm) (with ribs) typical standard model: 9ad1201h1h output circuit: open collector inside of dc fan pull-up resistor pull-up voltage 4 to 27.6 v dc photocoupler ic 10 ma max. sensor sensor output ( v ce ) air flow direction rotating direction air flow direction rotating direction lead wire mounting hole a wg24 ul1007 standard with sensor 1200.8 1200.8 104.80.3 104.80.3 4- 4.30.3 10010 380.5 60.5 60.5 1200.8 1200.8 104.80.3 104.80.3 4- 4.30.3 380.5 60.5 60.5 mounting hole connector: tyco electronics amp 171822-2 (pin1 sensor output: yellow pin2 : black) contact: tyco electronics amp 170262-1 120 9ad type startup delay: 18 3 sec. detection delay: 3 sec. max. trip point: 1700 min -1 * recommended connectors and contacts are listed below. connector: tyco electronics amp 172211-2 contact: tyco electronics amp 170376-1 air flow - static pressure characteristics wiring diagram (cfm) ( m 3 /min ) ( pa ) ( inch h 2 o ) 90 50 70 60 80 40 30 10 20 0 1 2 3 100 to 240 v 50/60 hz 4 0 50 100 150 0.4 0.2 0.3 0.1 0 fan fan photo coupler yellow black 10 ma max. +4 to 27.6 v dc senser output gnd (0 v) standard with sensor static pressure air ?ow ac power supply ac power supply pull-up resistor
3-33-1, minami-otsuka, toshima-ku, tokyo, 170-8451, japan tel: +81 3 5927 1020 http://www.sanyodenki.com the names of companies and/or their products speci?ed in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. ?san ace? is a trademark of sanyo denki co.,ltd. speci?cations are subject to change without notice. the products shown in this catalog are subject to japanese export control law. diversion contrary to the law of exporting country is prohibited. to protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. notice catalog no. c1032b001 ?13.12 option 10.5 0.5 4 - 11 0.5 124 1 104.8 0.3 124 1 104.8 0.3 4 - 4.3 0.3 4 - 2 0.5 resin filter kits model: 109-1000f13 (13ppi), 109-1000f20 (20ppi), 109-1000f30 (30ppi), 109-1000f40 (40ppi) plug cord model: 489-1635-l 10, 489-1635-l 21 42. 2 1.6 1.6 113 148 130 152.5 1.5 ` 0.5 5 1 0 4.3 0.3 outlet side 152.5 0.5 5 1 0 113 4.3 0.3 18.6 130 148 inlet side, outlet side 1.6 1.6 finger guards model: 109-019c surface treatment: nickel-chrome plating (silver) : 109-019h : cation electropainting (black) color model: 109-019e surface treatment: nickel-chrome plating (silver) : 109-019k : cation electropainting (black) color model l 10 l 21 power cord length (mm) 1,000 2,100 wiring harness for sensor model: 489-1636 pre-soldered 1000 20 10 1 pre-soldered 50 5 10 2 l 20 4 17 10 15.5 8 10 8 4 common speci?cations material ?????????????????????????? expected life ????????????????????? motor protection system ?????????? dielectric strength ???????????????? sound pressure level (spl) ???????? operating temperature ???????????? storage temperature ?????????????? mass ????????????????????????????? frame: plastics (flammability: ul94v-0), impeller: plastics (flammability: ul94v-1) refer to speci?cations (l10: survival rate: 90% at 60 , rated voltage, and continuously run in a free air state) burnout protection at locked rotor condition 50/60 hz, 1,500 vac, 1 minute (between power terminal and frame or between lead conductor and frame) expressed as the value at 1 m from air inlet side refer to speci?cations (non-condensing) 30 to 75 (non-condensing) approx. 290 g 120 120 38 mm [ m 3 /min ] [ cfm ] [ pa ] [ inchh 2 o ] model no. rated voltage [v] operating voltage range [v] rated current [a] frequency (note) [hz] rated input [w] max. air flow max. static pressure spl [ db(a)] operating temperature [ ] expected life [h ] rated speed min -1 0.08 9AD1201H12 4.4 3,250 3.0 106 84 0.34 42 100 to 240 90 to 264 20 to 75 60,000 50/60 note: 50/60 hz compatible. available options: pulse sensor lock sensor low speed sensor please contact us for details on the following speci?cations: speci?cations the model no. below has ribs and no sensors. for models without ribs, append "1" to the model no. (ribless model depicted) features low power consumption power consumption is reduced by approximately 72% compared with our conventional ac fan. * long life the san ace 120ad has an expected life of 60,000 hours (approximately 6 years), approximately 2.4 times that of our conventional ac fan. * wide range a rated voltage range of 100 to 240 vac allows for usage in both 100 vac and 200 vac systems. rotation speed remains constant even at different input voltages. * our conventional ac fan is 120 x 120 x 38 mm san ace 120 , model no. 109s072ul at a frequency of 60 hz. ac fan 120 9ad type


▲Up To Search▲   

 
Price & Availability of 9AD1201H12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X